Welcome To My Shop. Patient Monitor & ECG/EKG. Braces & Supports 88. Other Camera & Photo Accs. Clothing, Shoes & Accessories. Air Motor 2 holes. Air Motor 4 holes. Motor parts & Vehicle supply. Sale up to 20% off. Salon & Spa Tool Sale. With collective strong sound wave head, strong sound wave of 40KHZmay be emitted to vibrate fat cells at top speed and produce numerous vacuum air pockets inside and outside the fat cells, robustly impact fat cells to generate introverted blast and disintegrate triglyceride into glycerol and free fatty acids. Then RF waves at frequency of 1MHZ is used for exhausting the integrated glycerol and free fatty acids through hepatoenteral circulation. Finally vacuum RF and energy electrode are used for positioning and tightening fat In physics, t is known as “cavitation”. Micropore introverted blast inside and outside cell may lead to enhanced molecular motion and a higher energy level and this Will finally cause fat cell rupture and thereby achieve the effects of body building and losing weight. 2 Easy to operate, treatments are passive and require only the correct positioning of treatment pads, it will not compromise office staff time or productivity, won’t effect life and work after treatment, fast healing time. 3 Treat All Skin Types, Treat All Body Parts such as neck, breasts, back, knees, hips, thighs, bottom. 4 Accelerate tissue coagulation to avoid muscle slack after slimming. Instrument Function and Treatment Principles. Vacuum Bipolar RF handle. Dissolve fat, lymphatic drainage, firm skin and enhance skin elasticity. Body-shaping Equipment adopts the most advanced high-speed turbine negative pressure technology, and innovative three-dimensional conversion technology, combining with microcomputer chip controlled patent roller axis, and has an anti-geocentric attract effect on the skin. Attracting and outspreading the fibrillar connective tissue of different cortexes, through the rhythmic massage and effectively break down subcutaneous fat and reduce cellular tissue accumulation of fat, use of the patents to massage deeply roller different parts of the body, bring up fat layer in dermis, curium and subcutaneous, and release micro-vascular lymphatic vessels at the same time, promoting metabolism and to make fat cells in a passive movement to fat acids, even within the cells of toxins, also to be eliminated from lymphatic system in vitro the detoxitication enhance the fuction of as many as four times. Can be done manually or any other instruments can not achieve the perfect results. Sextupole body RF handle. Being integrated with the most advanced RF technology and radio frequency, the instrument may directly reach the deep-seated fat body and have the excellence of targeted positioning RF. In the fast-active state, fat cell tissue may generate friction heat, increase local temperature and remove excess fat and toxin from the body through sweat gland, enterohepatic circulation and lymph and ultimately achieve the effect of dissolving fat. With controlled depth technology, inlaid diamond particles of different sizes may rub skin alongits pattern, adjust suction strength by means of vacuum draw and rub with negative pressure strong force to directly explode thick fat. Thus, the effects are very obvious: Enhance blood circulation, accelerate the decomposition of fat, take away wastes, enhance the effect of removing cellulite, effectively improve the state of areolar tissue, remove stubborn fat and improve the sufficient absorption condition of diet products. 3.40Khz Ultrasonic handle. Strong sound wave explosion fat head With collective strong sound wave head, strong sound wave of 40KHZ may be emitted to human body for impacting fat cells fiercely and causing friction motion between fat cells. This may cause effective consumption of calories and moisture in fat cells and reduce the size of fat cells. What’s more, sound wave vibration Vmay cause fierce impact of fat cells to make them be exploded instantaneously, reduce the amount of fat cells and thereby achieve the effects of removing fat. Quadrupole RF handle –Facial wrinkle elimination, tightening and lifting. A capacitive coupling electrode is used for transmitting radio-wave energy and generating an electric field for entering into subcutaneous tissue through the skin surface. In the high-frequency of 450khz, this electric field changes its polarity for 450,000 times per second. As the papillary dermis collagen may immediately shrink when the temperature is within the range from 60 to 70 Celcius degree, after wrinkle treatment, client may immediately sense the skin tightening effects as it is being lifted and firmed. When collagen is produced continuously, thickness and density of the skin papillary dermis may be increased to remove wrinkles, eliminate scars, restore skin elasticity and gloss and make it be blonde and smooth. While collagen is increased, fresh skin is generated in the position of operation and wrinkles are removed by large amount of cells. In addition, when cortex without elasticity or that with thick horny layer in the area with wrinkles is separated, surrounding skin will also be renewed. Stick to enhance rejuvenation: use of positive and negative micro-current activation energy release skin cells, so that rapid synthesis of fibroblasts Collagen, elastic skin revert to the original compact, the skin causing t the skin to stimulate the muscle tension is increased, thereby gradually eliminate wrinkles prevent skin aging, restoring skin elasticity, facial improvement. Diode Lipo Laser emits low levels of laser energy, which creates a chemical signal in the fat cells, breaking down the stored triglycerides into free fatty acids and glycerol and releasing them though channels in the cell membranes. The fatty acids and glycerol are then transported around the body to the tissues that will use them during metabolism to create energy. This process of fatty acid release is a natural response of the body when the body needs to used stored energy reserves, thus it is not creating any unnatural reaction in the body nor does it affect or damage any surrounding structures such as skin, blood vessels and peripheral nerves. A period of exercise post treatment will ensure the complete metabolism and thus elimination from the body of the freed fatty acids. This 5mw lipo laser system can adopts light to penetrate skin deep level to stimulate metabolism in result in keep result after slimming treatment Tied laser board band at the site of the need to lose weight, make laser for 20 minutes. Laser diode, wavelength: 635nm 650nm. Energy output :56 x 180mW. Mains power output: 100VA. Safety :On board diagnostics. Classification :Electrical Class 1, Type B applied part. 140K Cellulite Fat Remove Machine. 1Vacuum Bipolar RF handle. 1Sextupole body RF handle. Statement:The sale of this item may be subject to regulation by the U. Food and Drug Administration and state and local regulatory agencies. The Fingertip Pulse Oximeter is certified with the US FDA 510K No. K070371, the CE & TUV of Eureope and it is on the Australian Register of Therapeutic Goods (ARTG) with the code 136606. The Powered Surgical Instrument / Speed 808 System is certified with the US FDA 510(k) Number:K132989. The Powered Surgical Instrument / Hair Remove Device is certified with the US FDA 510(k) Number:K180353. The Powered Surgical Instrument / Hair Remove System is certified with the US FDA 510(k) Number:K141973. Massager, vacuum, light induced heating / Slimming Treatment Device is certified with the US FDA 510(k) Number:K161892. You pay us what you see on the invoice, i. Please make sure it is correct. Or replace item for you free of charge. This item is in the category “Business & Industrial\Healthcare, Lab & Dental\Medical & Lab Equipment, Devices\Aesthetic & Cosmetic Machines”. The seller is “jxkyauto” and is located in this country: US. This item can be shipped to United States.
- Custom Bundle: No
- Modified Item: No
- Country/Region of Manufacture: China
- Expiration Date: Brand New
- Feature 1: Dissolve fat
- Feature 2: lymphatic drainage
- Marke: Unbranded
- Feature 3: firm skin and enhance skin elasticity
- Feature 4: Strong force explosion fat and fat removal
- Feature 5: Vacuum RF
- Feature 6: Bipolar Tripolar RF Facial wrinkle elimination
- 510(k) Number: K161892
- Brand: Carejoy