WL-JKL808a [common] – Bipolar RF Ultrasonic Cavitation Vacuum Fat. Bipolar RF Negative +Microcurrent+Vacuum+40KHz Ultrasound Cavitation Fat System Slimming Machine. Bipolar RF Ultrasonic Cavitation Vacuum Fat. Bipolar RF Ultrasonic Cavitation Vacuum Slimming Machine Weight Fat Cellulite Reduction. Model: WL-JKL808a #ID: 1000640. 40K Cavitation for Slimming Fat Removal. Vacuum Pressure RF for Body Massage. Bipolar Radio Frequency RF for Eyes and Face. Microcurrent Bio Fat Reduce Body Shape. With collective strong sound wave head, strong sound wave of 40000HZ may be emitted to vibrate fat cells at top speed and produce numerous vacuum air pockets inside and outside the fat cells, robustly impact fat cells to generate introverted blast and disintegrate triglyceride into glycerol and free fatty acids. Then RF waves at frequency of 1M HZ is used for exhausting the integrated glycerol and free fatty acids through hepatoenteral circulation. Finally, vacuum RF and energy electrode are used for positioning and tightening fat. In physics, it is known as “cavitation”. Micropore introverted blast inside and outside cell may lead to enhanced molecular motion and a higher energy level and this will finally cause fat cell rupture and thereby achieve the effects of body building and losing weight. Dissolve fat, lymphatic drainage, firm skin and enhance skin elasticity Negative RF head Being integrated with the most advanced RF technology and radio frequency, the instrument may directly reach the deep-seated fat body and have the excellence of targeted positioning RF. In the fast-active state, fat cell tissue may generate friction heat, increase local temperature and remove excess fat and toxin from the body through sweat gland, enterohepatic circulation and lymph and ultimately achieve the effect of dissolving fat. With controlled depth technology, inlaid diamond particles of different sizes may rub skin alongits pattern, adjust suction strength by means of vacuum draw and rub with negative strongforce to directly explode thick fat. Thus, the effects are very obvious: Enhance blood circulation, accelerate the decomposition of fat, take away wastes, enhance the effect of removing cellulite, effectively improve the state of areolar tissue, remove stubborn fat and improve the sufficient absorption condition of diet products. Strong force explosion fat and fat removal Strong sound wave explosion fat head With collective strong sound wave head, strong sound wave of 40000HZ may be emitted to human body for impacting fat cells fiercely and causing friction motion between fat cells. This may cause effective consumption of calories and moisture in fat cells and reduce the size of fat cells. What’s more, sound wave vibration may cause fierce impact of fat cells to make them be exploded instantaneously, reduce the amount of fat cells and thereby achieve the effects of removing fat. Body Vacuum RF Probe For body and face re-shaping. Weight loss Vaccum+RF fat-explosion machine can promote tissue metabolism, repel the cellulite, which make fat granule in different depths and shocking make fusion energy, and the deepest receptor can get granule in 3CM thick of skin, and rapid expansion and the rapid heating of the cell wall that exceed the elastic limits and arises cells broken, so that the combustion of fatty acids at the same time broken out of a pot, not only the burning consumption of fatty acids but also more directly emptying so rapidly reduce the size of granule 4. Facial wrinkle elimination, tightening and lifting Facial RF head A capacitive coupling electrode is used for transmitting radio-wave energy and generating an electric field for entering into subcutaneous tissue through the skin surface. In the high-frequency of 450khz, this electric field changes its polarity for 450,000 times per second. To reply to the rapid change in electrode, directions of electrical particles the skin are also changed. By this time, natural electric resistance in the subcutaneous tissue moves and generates heat energy. As thepapillary dermis collagen may immediately shrink when the temperature is within the range from 60 to 70 Celcius degree, after wrinkle operation, client may immediately sense the skin tightening effects as it is being lifted and firmed. When collagen is produced continuously, thickness and density of the skin papillary dermis may be increased to remove wrinkles, eliminate scars, restore skin elasticity and gloss and make it be blonde and smooth. While collagen is increased, fresh skin is generated in the position of operation and wrinkles are removed by large amount of cells. In addition, when cortex without elasticity or that with thick horny layer in the area with wrinkles is separated, surrounding skin will also be renewed. The entire process is completed without the need of surgery and anesthesia. Does not cause the phenomenon of uneven skin. Does not cause the phenomenon of bleeding, swelling and blood stasis. Without side effects and the risk of gaining the weight back, the results are rather obvious. Non-invasive does not affect the normal work and life. Functions Firm the arms, legs, thighs, buttocks, waist, back, abdominal muscles and reshape the body figure Improve and treat the orange peel like fatty tissues of different serious levels With the effects of soothing, decompression and pain relief (such as joint pain, sciatica), promote the regular mechanical aerobic exercise of skin tissue, rapidly relieve stress and remove fatigue. Firm, lift and compact the skin and mould the face shape Circulate and activate cells, promote metabolism and so that 100% more collagen and elastic fibers may be gained for improving the facial and body skin. Multipolar RF head(Tripolar RF) X 1 40KHz Cavitation Head X 1 Vacuum Biploar Head x 1 Bipolar RF Head for face X 2 Power cord x 1. Negative RF head Press “TIME SET” to adjust the time, adjust the operating rod “RF CHANNE” to “FACE” i. Start facial RF head operation, adjust the operating rod “RF CHANNE” to “BODY” i. Start body vacuum RF head operation, press “PAUSE THERE ELECTRODE RF” to start RF operation, press “RF ENERGY” and then “+” to increase the RF intensity or “-” to decrease RF intensity, press “AIR PUMP PAUSE” to start the operation of negative vacuum RF head. Apply gel to the negative vacuum RF head, point it to the position for losing weight and operate in pulling technique (drag fat at the position for losing weight to the position where it is closer to the lymph gland) for about 20 minutes. Spread gel or essence on the treated positions for hairdressing evenly 2. In use, start with low-energy. We suggest to try for the proper energy level on the back of clients’ hands before using on body of them 3. Do not use essential oil as the medium 4. In operation, start pulling only after negative head is attached to skin. Turn off the instrument probe when it is not in use. Press “PAUSE” to start the strong sound wave explosion fat head Mode a. D means that: “A” is continuous working for 3 sec and discontinuous for 2 sec. “B” is continuous working for 4 sec and discontinuous for 3sec. “C” is continuous working for 1 sec and discontinuous for 1 sec. “D” is continuous working for 0.5 sec and discontinuous for 0.5sec. Body RF Probe(Vacuum) Panel: Press “RF CHANNEL” in the display screen to select body RF output, select the suitable intensity adjust according to the customer’s acceptable level, 3-6 is ok. , and at last press PAUSE key. The face RF starts to work. Beautifying: Use the probe to massage the specific part of skin circularly after applying the sliming cream for about 30 to 40 minutes. It could quicken the blood circulation in the part of skin treated and has the effect of decomposing fat, etc. Matters needing attention: 1. Apply sliming cream or cooling gel to the part of skin to be treated before the operation. Keep close contact between the probe and the skin. Adjust the intensity from low level to high level. Please do not irradiate eyeball directly with colored light. Facial RF head Press “TIME SET” to adjust the time, adjust the operating rod “RF CHANNE” to “FACE” and press “PAUSE THERE ELECTRODE RF”to start RF operation; press “RF ENERGY” and then “+” to increase the RF intensity or “-” to decrease RF intensity. Adjust to a proper level according to acceptability of clients. Generally speaking, levels 3 6 are OK. Spread gel or wrinkle smoothing essence on the treated positions for hairdressing (generally 20-30G each time), operate with the facial RF head for 15-20 minutes with mainly the spiral movement on face. THIGH Treated time: 30 minutes 1. From down to upper, pushing to the groin to dredge the lymph. From down to upper, circling push by anticlockwise, can help decomposing fatness. Also can push by come-and-go to decompose fatness. Pull from the knee and muscle texture to upper, can improve the curve. Treated time:20 to 30 minutes 1. Along the lymph direction, pulling to the waist. From upper to down, by anticlockwise gesture, pull come-and-go. Along the muscle of arm, pull up to lift and tight the muscle. BACK Treated time: 20 to 30 minutes 1. First by come-and-go, pushing the bladder nerve 2 to 3 times. Circling by anticlockwise to stimulate the underarm lymph node. On the back, by anticlockwise circling, can help to decompose the fatness. Using lymph drainage gesture, pull the toxin to the lymph node, can help improving the back curve. ARM Treated time:30 minutes BACK SIDE 1. From the inner elbow to the armpit, doing lymph drainage. Circling to stimulate the lymph node. By anticlockwise or come-and-go pushing, decomposing the fatness. From the elbow to the oxter, doing tightening gesture. Abdomen Treated time:20 to 30 minutes 1. From small to large, by clockwise direction, circling arrond the navel, can help peristalsis of the large intestine. From small to large, by anticlockwise direction, circling push down. From the belly and muscle texture, pull to the groin. Through lymph drainage gesture, taking the toxin to the place of groin. Notice: Those do not use the machine: 1. Pregnant women or women during in menses. Patient whose wound after operation has not healed up. Acute inflammation or epidemical patients. Whom with heart diseases or with heart pacemaker.. Whom with kidney (gall-stone) disease. Who was embedded metal object or silica gel. Who in menses, birth control period, emiction incontinence period, or accepting the belly operation. Whose body always take much inner hot. Who has the genetic hypersensitivity. Be sure to use the special ultrasonic gel. Avoid knocking the us head. For avoiding burning the head, during operation, please prepare enough ultrasoinc gel. Don’t stay in one place, avoid treating on the bone. Don’t use disinfectant product to disinfect the us head. We suggest the wet cotton or dry towel enough. Check the machine power cord if it is connected well. If the machine will not use for a loing time, please switch off it, and power off. Please take off all metal decoration from the operator and patients body. If continuous using 1 hour, please pause the machine about 10 minutes, then using again. During the operation, be sure not to accept other operation. Power suppy Input:110V/220V 60HZ/50HZ Power :130W 40K cavitation head: Power supply output:150V Frequency:40KHz Power:25W Vacuum+Bipolar RF head: Power supply output:66V Freqeuncy:450K Power:95W BIO head: Power supply output:24V Freqeuncy:1.5K Power:1W Tripolar RF head: Power supply output:66V Freqeuncy:450K Power:35W Face RF head: Power supply output:66V Freqeuncy:450K Power:35W. The item “Vacuum Ultrasonic Cavitation Multipolar Radio Frequency Microcurrent RF Machine” is in sale since Tuesday, March 13, 2012. This item is in the category “Business & Industrial\Healthcare, Lab & Life Science\Medical Equipment\Other Medical Equipment”. The seller is “forskincare” and is located in shenzhen,guangdong. This item can be shipped worldwide.
- Brand: Unbranded
- MPN: WL-JKL808a-FO-US
- Country/Region of Manufacture: China